SRK35ZMP-S / SRC35ZMP-S

SRK35ZMP-S
Wall mounted – Indoor Unit

The SRK35ZMP-S is a wall-mounted RAC indoor unit with a nominal cooling capacity of 3.5 kW.

srk-zmp_il_141013121033

Technical Specifications

Data Sheet (Printer Friendly) Download

General Data

Nominal cooling capacity (min-max) kW 3.2 (0.9 – 3.5)
Nominal heating capacity (min-max) kW 3.6 (0.9 – 4.3)
Exterior Dimensions (H x W x D) mm 262 x 769 x 210
Net Weight kg 7.2
Air Flow Cooling (Hi/Me/Lo) m3/min 9.5 / 6.8 / 4.2
Air Flow Heating (Hi/Me/Lo) m3/min 9.6 / 7.4 / 5.5
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 47 / 36 / 23
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 44 / 36 / 28

Schematics

srk25-35-45zmp-s_isl1_141013121033

SRC35ZMP-S
Wall mounted – Outdoor Unit

The SRC35ZMP-S is a RAC outdoor unit with a nominal cooling capacity of 3.5 kW.

src-zmp_ol_141013121033

Technical Specification

General Data

Nominal cooling capacity (min-max) kW 3.2 (0.9 – 3.5)
Nominal heating capacity (min-max) kW 3.6 (0.9 – 4.3)
EER (Energy Label) 3.22
COP (Energy Label) 3.62
Exterior Dimensions (H x W x D) mm 540 x 645(+57) x 275
Net Weight kg 27
Sound Pressure Level (Cooling/Heating) dB(A) 49 / 48
Energy class (cooling/heating) A++/A+
SEER “Average climate”/(Energy label) 6.15
SCOP “Average climate”/(Energy label) 4

Elecrical Data

Pdesignc kW 3.2
Pdesignh (@-10°C) kW 3
Annual electricity consumption (cooling/heating) kWh/a 183/1052
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 4.9 / 4.7 / 4.5
Max. running current A 9
Power consumption (cooling/heating) kW 0.995 / 0.995

Installation

Refrigerant (GWP) R410A (1975)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 9.52 (3/8″)
Ref. Max Piping Length m Max. 15
Vertical Height differences / Outdoor is higher/lower m Max. 10 / Max. 10

Schematics

srk25-35-45zmp-s_isl1_141013121033