SRK35ZM-S / SRC35ZM-S

SRK35ZM-S
Wall mounted – Indoor Unit

The SRK35ZM-S is a wall mounted RAC indoor unit with a nominal cooling capacity of 3.5 kW.

srk-zj-_il_150514154535

Technical Specifications

General Data

Nominal cooling capacity (min-max) kW 3.5 (1.0 – 3.8)
Nominal heating capacity (min-max) kW 4.0 (1.3 – 4.8)
Exterior Dimensions (H x W x D) mm 294 x 798 x 229
Net Weight kg 9.5
Air Flow Cooling (Hi/Me/Lo) m3/min 10.1 / 6.4 / 5.0
Air Flow Heating (Hi/Me/Lo) m3/min 12.8 / 9.4 / 6.1
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 42 / 32 / 22
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 43 / 37 / 25

Schematics

srk20_25_35_50zj-s_isl1_150514154535

SRC35ZM-S
Wall mounted – Outdoor Unit

The SRC35ZM-S is a RAC outdoor unit with a nominal cooling capacity of 3.5 kW.

src20-35zj_ol_150514154535

Technical Specifications

Data Sheet (Printer Friendly)

General Data

Nominal cooling capacity (min-max) kW 3.5 (1.0 – 3.8)
Nominal heating capacity (min-max) kW 4.0 (1.3 – 4.8)
EER (Energy Label) 3.47
COP (Energy Label) 4
Exterior Dimensions (H x W x D) mm 540 x 780(+62) x 290
Net Weight kg 35
Sound Pressure Level (Cooling/Heating) dB(A) 50 / 51
Energy class (cooling/heating) A++/A+
SEER “Average climate”/(Energy label) 6.87
SCOP “Average climate”/(Energy label) 4.17

Elecrical Data

Pdesignc kW 3.5
Pdesignh (@-10°C) kW 3.2
Annual electricity consumption (cooling/heating) kWh/a 179/1074
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 4.9 / 4.7 / 4.5
Max. running current A 9
Power consumption (cooling/heating) kW 1.01 / 1.00

Installation

Refrigerant (GWP) R410A (1975)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 9.52 (3/8″)
Ref. Max Piping Length m Max. 15
Vertical Height differences / Outdoor is higher/lower m Max. 10 / Max. 10