SRK20ZM-S / SRC20ZM-S

The SRK20ZM-S is a wall mounted RAC indoor unit with a nominal cooling capacity of 2.0 kW.

srk-zj-_il_150514152145

Technical Specifications

General Data

Nominal cooling capacity (min-max) kW 2.0 (1.0 – 2.7)
Nominal heating capacity (min-max) kW 2.7 (1.2 – 3.9)
Exterior Dimensions (H x W x D) mm 294 x 798 x 229
Net Weight kg 9.5
Air Flow Cooling (Hi/Me/Lo) m3/min 7.8 / 5.6 / 4.8
Air Flow Heating (Hi/Me/Lo) m3/min 9.8 / 6.3 / 5.0
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 33 / 27 / 21
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 36 / 31 / 24

Schematics

Front View

SRC20ZM-S
Wall mounted – Outdoor Unit

The SRC20ZM-S is a RAC outdoor unit with a nominal cooling capacity of 2.0 kW.


SRK20ZM-S / SRC20ZM-S

Technical Specifications

Data Sheet (Printer Friendly)

General Data

Nominal cooling capacity (min-max) kW 2.0 (1.0 – 2.7)
Nominal heating capacity (min-max) kW 2.7 (1.2 – 3.9)
EER (Energy Label) 4.55
COP (Energy Label) 4.35
Exterior Dimensions (H x W x D) mm 540 x 780(+62) x 290
Net Weight kg 32
Sound Pressure Level (Cooling/Heating) dB(A) 47 / 46
Energy class (cooling/heating) A++/A+
SEER “Average climate”/(Energy label) 6.45
SCOP “Average climate”/(Energy label) 4.05

Elecrical Data

Pdesignc kW 2
Pdesignh (@-10°C) kW 2.8
Annual electricity consumption (cooling/heating) kWh/a 109/967
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 3.2 / 3.1 / 3.0
Max. running current A 9
Power consumption (cooling/heating) kW 0.44 / 0.62

Installation

Refrigerant (GWP) R410A (1975)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 9.52 (3/8″)
Ref. Max Piping Length m Max. 15
Vertical Height differences / Outdoor is higher/lower m Max. 10 / Max. 10

Schematics