SRF50ZMX-S1 / SRF50ZMX-S

SRF50ZMX-S1
Floor standing – Indoor Unit

The SRF50ZMX-S1 is a floor standing RAC indoor unit with a nominal cooling capacity of 5.0 kW.

srf-close-s_il_160514130026

Technical

General Data

Nominal cooling capacity (min-max) kW 5.0 (1.1 – 5.2)
Nominal heating capacity (min-max) kW 6.0 (0.6 – 6.9)
Exterior Dimensions (H x W x D) mm 600 x 860 x 238
Net Weight kg 19
Air Flow Cooling (Hi/Me/Lo) m3/min 11.5 / 9.6 / 6.6
Air Flow Heating (Hi/Me/Lo) m3/min 12.0 / 10.0 / 7.6
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 46 / 42 / 32
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 47 / 41 / 33

Schematics

srf25_35_50zjx-s_isl1_160514152345

SRF50ZMX-S
Floor standing – Outdoor Unit

The SRF50ZMX-S is a floor standing RAC outdoor unit with a nominal cooling capacity of 5.0 kW.

srf-close-s_il_160514130026
SRF50ZMX-S1 / SRF50ZMX-S

Technical Specifications

General Data

Nominal cooling capacity (min-max) kW 5.0 (1.1 – 5.2)
Nominal heating capacity (min-max) kW 6.0 (0.6 – 6.9)
EER (Energy Label) 3.24
COP (Energy Label) 3.82
Exterior Dimensions (H x W x D) mm 640 x 800(+71) x 290
Net Weight kg 38
Sound Pressure Level (Cooling/Heating) dB(A) 63 / 62
Energy class (cooling/heating) A+/A+
SEER “Average climate”/(Energy label) 6.01
SCOP “Average climate”/(Energy label) 4.07

Elecrical Data

Pdesignc kW 5
Pdesignh (@-10°C) kW 5
Annual electricity consumption (cooling/heating) kWh/a 292 / 1722
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 7.1 / 6.8 / 6.5
Max. running current A 15
Power consumption (cooling/heating) kW 1.390 / 1.540

Installation

Refrigerant (GWP) R410A (1975)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 9.52 (3/8″)
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics

srf25_35_50zjx-s_osl1_070814130332