SRR25ZJ-S / SRC25ZMX-S

SRR25ZJ-S
Ceiling concealed – Indoor Unit

The SRR25ZJ-S is a ceiling concelaed RAC indoor unit with a nominal cooling capapcity of 2.5 kW.

srr_il_160514123442

Technical Specifications

General Data

Nominal cooling capacity (min-max) kW 2.55 (0.9 – 3.2)
Nominal heating capacity (min-max) kW 3.4 (0.9 -3.2)
Exterior Dimensions (H x W x D) mm 230 x 740 x 455
Net Weight kg 22
Air Flow Cooling (Hi/Me/Lo) m3/min 8.5 / 7.0 / 5.0
Air Flow Heating (Hi/Me/Lo) m3/min 10.0 / 9.0 / 6.5
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 40 / 35 / 29
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 41 / 38 / 31

Schematics

srr25_35_50_60zj_isl1_160514123442
SRC25ZMX-S

Ceiling concealed – Outdoor Unit

The SRC25ZMX-S is a RAC outdoor unit with a nominal cooling capacity of 2.5 kW.

src20-35zjx-hyper_ol_140514095546
SRR25ZJ-S / SRC25ZMX-S

Technical Specifications

General Data

Nominal cooling capacity (min-max) kW 2.55 (0.9 – 3.2)
Nominal heating capacity (min-max) kW 3.4 (0.9 -3.2)
EER (Energy Label) 4.31
COP (Energy Label) 4.53
Exterior Dimensions (H x W x D) mm 595 x 780(+62) x 290
Net Weight kg 38
Sound Pressure Level (Cooling/Heating) dB(A) 47 / 47
Energy class (cooling/heating) A++/A
SEER “Average climate”/(Energy label) 6.12
SCOP “Average climate”/(Energy label) 3.96

Elecrical Data

Pdesignc kW 2.5
Pdesignh (@-10°C) kW 2.9
Annual electricity consumption (cooling/heating) kWh/a 144 / 1025
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 3.7 / 3.6 / 3.4
Max. running current A 9
Power consumption (cooling/heating) kW 0.58 / 0.75

Installation

Refrigerant (GWP) R410A (1975)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 9.52 (3/8″)
Ref. Max Piping Length m Max. 15
Vertical Height differences / Outdoor is higher/lower m Max. 10 / Max. 10