FDTC40VF / SRC40ZMX-S

FDTC40VF
Ceiling cassette – Indoor Unit

The FDTC40VF is a ceiling cassette RAC indoor unit with a nominal cooling capapcity of 4.0 kW.

fdtc_il_160514115226

Technical Specifications

General Data

Nominal cooling capacity (min-max) kW 4.0 (1.1 – 4.7)
Nominal heating capacity (min-max) kW 4.5 (0.6 -5.4)
Exterior Dimensions (H x W x D) mm Unit: 248 x 570 x 570 Panel: 35 x 700 x 700
Net Weight kg 18.5 (Unit: 15 Panel: 3.5)
Air Flow Cooling (Hi/Me/Lo) m3/min 11.5 / 9 / 7
Air Flow Heating (Hi/Me/Lo) m3/min 11.5 / 9 / 8
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 42 / 36 / 30
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 42 / 36 / 32

Schematics

fdtc25-60vf_isl1_160514115226
Front View

SRC40ZMX-S
Ceiling cassette – Outdoor Unit

The SRC40ZMX-S is a RAC outdoor unit with a nominal cooling capacity of 4.0 kW.


FDTC40VF / SRC40ZMX-S

Technical Specifications

General Data

Nominal cooling capacity (min-max) kW 4.0 (1.1 – 4.7)
Nominal heating capacity (min-max) kW 4.5 (0.6 -5.4)
EER (Energy Label) 3.85
COP (Energy Label) 4.06
Exterior Dimensions (H x W x D) mm 640 x 800(+71) x 290
Net Weight kg 45
Sound Pressure Level (Cooling/Heating) dB(A) 50 / 50
Energy class (cooling/heating) A++/A
SEER “Average climate”/(Energy label) 6.49
SCOP “Average climate”/(Energy label) 3.96

Elecrical Data

Pdesignc kW 4
Pdesignh (@-10°C) kW 4
Annual electricity consumption (cooling/heating) kWh/a 216 / 1415
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 5
Max. running current A 12
Power consumption (cooling/heating) kW 1.04 / 1.10

Installation

Refrigerant (GWP) R410A (1975)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 12.7 (1/2″)
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20