FDTC35VF / SRC35ZMX-S

FDTC35VF
Ceiling cassette – Indoor Unit

The FDTC35VF is a ceiling cassette RAC indoor unit with a nominal cooling capacity of 3.5 kW.

fdtc_il_160514111728

Technical Specifications

General Data

Nominal cooling capacity (min-max) kW 3.6 (0.9 – 4.1)
Nominal heating capacity (min-max) kW 4.25 (0.9 – 5.1)
Exterior Dimensions (H x W x D) mm Unit: 248 x 570 x 570 Panel: 35 x 700 x 700
Net Weight kg 18.5 (Unit: 15 Panel: 3.5)
Air Flow Cooling (Hi/Me/Lo) m3/min 9.5 / 9 / 7
Air Flow Heating (Hi/Me/Lo) m3/min 10 / 9 / 8
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 40 / 36 / 30
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 42 / 35 / 32

Schematics

fdtc25-60vf_isl1_160514111728

SRC35ZMX-S
Ceiling cassette – Outdoor Unit

The SRC35ZMX-S is a RAC outdoor unit with a nominal cooling capacity of 3.5 kW.

src20-35zjx-hyper_ol_140514095546
FDTC35VF / SRC35ZMX-S

Technical Specifications

General Data

Nominal cooling capacity (min-max) kW 3.6 (0.9 – 4.1)
Nominal heating capacity (min-max) kW 4.25 (0.9 – 5.1)
EER (Energy Label) 3.36
COP (Energy Label) 3.66
Exterior Dimensions (H x W x D) mm 595 x 780(+62) x 290
Net Weight kg 38
Sound Pressure Level (Cooling/Heating) dB(A) 50 / 50
Energy class (cooling/heating) A++/A+
SEER “Average climate”/(Energy label) 6.29
SCOP “Average climate”/(Energy label) 4.04

Elecrical Data

Pdesignc kW 3.6
Pdesignh (@-10°C) kW 3.3
Annual electricity consumption (cooling/heating) kWh/a 201 / 1145
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 5.3
Max. running current A 9
Power consumption (cooling/heating) kW 1.07 / 1.16

Installation

Refrigerant (GWP) R410A (1975)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 9.52 (3/8″)
Ref. Max Piping Length m Max. 15
Vertical Height differences / Outdoor is higher/lower m Max. 10 / Max. 10