FDEN71VNXVF1

FDEN71VF1
Ceiling Suspended – Indoor Unit

The FDEN71VF1 is a ceiling suspended PAC indoor unit with a nominal cooling capacity of 7.1 kW.

fden_il_151013113357

Technical Specifications

Download Print Friendly Data Sheet HERE…

General Data

Nominal cooling capacity (min-max) kW 7.1 (3.2 – 8.0)
Nominal heating capacity (min-max) kW 8.0 (3.6 – 9.0)
Exterior Dimensions (H x W x D) mm 210 x 1320 x 690
Net Weight kg 37
Air Flow Cooling (Hi/Me/Lo) m3/min 16 / 14 / 12
Air Flow Heating (Hi/Me/Lo) m3/min 16 / 14 / 12
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 41 / 39 / 38
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 41 / 39 / 38

Schematics

fden_isl1_151013113357

FDC71VNX
Ceiling Suspended – Outdoor Unit

The FDC71VNX is a PAC outdoor unit with a nominal cooling capacity of 7.1 kW.

src71_ol_231013154604

Technical Specifications

General Data

Nominal cooling capacity (min-max) kW 7.1 (3.2 – 8.0)
Nominal heating capacity (min-max) kW 8.0 (3.6 – 9.0)
EER (Energy Label) 3.36
COP (Energy Label) 3.79
Exterior Dimensions (H x W x D) mm 750 x 880 (+88) x 340
Net Weight kg 60
Sound Pressure Level (Cooling/Heating) dB(A) 51 / 48
Energy class (cooling/heating) B/A
SEER “Average climate”/(Energy label) 4.67
SCOP “Average climate”/(Energy label) 3.8

Elecrical Data

Pdesignc kW 7.1
Pdesignh (@-10°C) kW 6.5
Annual electricity consumption (cooling/heating) kWh/a 532 / 2394
Power Source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 17
Power consumption (cooling/heating) kW 2.11 / 2.11

Installation

Refrigerant (GWP) R410A (1975)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 9.52 (3/8″) / 15.88 (5/8″)
Ref. Max Piping Length m Max. 50
Vertical Height differences / Outdoor is higher/lower m Max. 30 / Max. 15

Schematics

fdc70vnx-temp_file_osl1_151013102646