FDEN60ZJXVF

FDEN60VF
Ceiling Suspended – Indoor Unit

The FDEN60VF is a ceiling suspended PAC indoor unit with a nominal cooling capacity of 6.0 kW.

fden_il_151013113357

Technical Specifications

Download Print Friendly Data Sheet HERE…

General Data

Nominal cooling capacity (min-max) kW 5.6 (1.1 – 6.3)
Nominal heating capacity (min-max) kW 6.7 (0.6 – 7.1)
Exterior Dimensions (H x W x D) mm 210 x 1320 x 690
Net Weight kg 37
Air Flow Cooling (Hi/Me/Lo) m3/min 16 / 14 / 12
Air Flow Heating (Hi/Me/Lo) m3/min 16 / 14 / 12
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 41 / 39 / 38
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 41 / 39 / 38

Schematics

fden_isl1_151013113357

SRC60ZMX-S
Ceiling Suspended – Outdoor Unit

The SRC60ZMX-S is a PAC outdoor unit with a nominal cooling capacity of 6.0 kW.

src40-60zjx_ol_141013154424

Technical Specifications

General Data

Nominal cooling capacity (min-max) kW 5.6 (1.1 – 6.3)
Nominal heating capacity (min-max) kW 6.7 (0.6 – 7.1)
EER (Energy Label) 3.15
COP (Energy Label) 3.58
Exterior Dimensions (H x W x D) mm 640 x 800 (+71) x 290
Net Weight kg 45
Sound Pressure Level (Cooling/Heating) dB(A) 54 / 54
Energy class (cooling/heating) A+/A
SEER “Average climate”/(Energy label) 5.7
SCOP “Average climate”/(Energy label) 3.8

Elecrical Data

Pdesignc kW 5.6
Pdesignh (@-10°C) kW 5
Annual electricity consumption (cooling/heating) kWh/a 344 / 1841
Power Source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 15
Power consumption (cooling/heating) kW 1.78 / 1.87

Installation

Refrigerant (GWP) R410A (1975)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 12.7 (1/2″)
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics

src40-50-60zjx.src50zj-s_osl1_151013104046